| Brand |
FARO |
| System |
Photon 20 |
| Date of introduction |
March 2009 |
| Weight [kg] (sensor only) |
14.5 |
| Size [cm] (sensor only) |
41 x 16 x 28 |
| Battery internal/external |
external |
| Laser Ranger |
- |
| Range measurement principle [1] |
phase |
| Wavelength [nm] |
785 |
| Laser safety classification |
3R |
| Min. / max. range [m] |
0.6 / 120 |
| Range accuracy [mm] (1 sigma) |
2mm at 10m and 25m, each at 90% and 10% reflectivity |
| Beam diameter at exit [mm] |
3.3 |
| Beam divergence/spot at 50 m distance [mm] |
0.16mrad (0.009°) |
| Hits per point before averaging |
N/A |
| Scanning Characteristics |
- |
| Max. FoV VxH [D] |
320 x 360 |
| Scan angle step size H/V [D] |
0.009 / 0.009 |
| Beam deflection mechanism |
rotating mirror |
| Measurement rate [2] [kHz] |
122 - 976 |
| Scan duration typical/highest resolution [min] |
variable |
| Operation Characteristics |
- |
| Temperature range/humidity range [°C/ %] |
5 to 40 / non condensing |
| Internal Camera [Y/N] |
N |
| Inbuild Control Panel [Y/N] |
Power and Start/Stop button on the scanner |
| Scan time per battery [h] |
6 |
| Peripherals |
- |