| Brand |
Trimble |
| System |
FX |
| Date of introduction |
2008 |
| Weight [kg] (sensor only) |
11 |
| Weight [kg] (sensor + peripherals) |
variable |
| Size [cm] (sensor only) |
42.5 x 16.4 x 23.7 |
| Battery internal/external |
external |
| Laser Ranger |
- |
| Range measurement principle [1] |
phase |
| Wavelength [nm] |
685 |
| Laser safety classification |
3R |
| Min. / max. range [m] |
1 / 80 |
| Range resolution [mm] |
variable |
| Range accuracy [mm] (1 sigma) |
1-pass HQ: 2.4
2-pass: 1.5 |
| Beam diameter at exit [mm] |
N/A |
| Beam divergence/spot at 50 m distance [mm] |
16 |
| Intensity recording (Y[#bits]/N) |
Y |
| Hits per point before averaging |
variable |
| Scanning Characteristics |
- |
| Max. FoV VxH [D] |
360 x 270 |
| Scan angle step size H/V [D] |
0.0171 x 0.0342 |
| Scan angle accuracy H/V [D] (1 sigma) |
0.008 |
| Beam deflection mechanism |
rotating mirror |
| Measurement rate [2] [kHz] |
216 |
| Scan duration typical/highest resolution [min] |
variable |
| Operation Characteristics |
- |
| Temperature range/humidity range [°C/ %] |
5 to 45 |
| Internal Camera [Y/N] |
N |
| Inbuild Control Panel [Y/N] |
N |
| Scan time per battery [h] |
variable |